ramips: fix reporting effective VLAN ID on MT7621 switches

On MT7621, the REG_ESW_VLAN_VTIM reads are undefined, causing swconfig
to always report `vid: 0` in swconfig show output.

Since a 4K VLAN table is used on this platform, the VLAN ID always
correponds to the actual VLAN table index so provide a specific MT7621
implementation of the get_vid callback which returns the table index
as VLAN ID.

Signed-off-by: Jo-Philipp Wich <jo@mein.io>
v19.07.3_mercusys_ac12_duma
Jo-Philipp Wich 6 years ago
parent 341b1427fc
commit dc7a1e8555

@ -478,6 +478,14 @@ mt7530_set_vid(struct switch_dev *dev, const struct switch_attr *attr,
return 0;
}
static int
mt7621_get_vid(struct switch_dev *dev, const struct switch_attr *attr,
struct switch_val *val)
{
val->value.i = val->port_vlan;
return 0;
}
static int
mt7530_get_vid(struct switch_dev *dev, const struct switch_attr *attr,
struct switch_val *val)
@ -835,6 +843,17 @@ static const struct switch_attr mt7621_port[] = {
},
};
static const struct switch_attr mt7621_vlan[] = {
{
.type = SWITCH_TYPE_INT,
.name = "vid",
.description = "VLAN ID (0-4094)",
.set = mt7530_set_vid,
.get = mt7621_get_vid,
.max = 4094,
},
};
static const struct switch_attr mt7530_port[] = {
{
.type = SWITCH_TYPE_STRING,
@ -866,8 +885,8 @@ static const struct switch_dev_ops mt7621_ops = {
.n_attr = ARRAY_SIZE(mt7621_port),
},
.attr_vlan = {
.attr = mt7530_vlan,
.n_attr = ARRAY_SIZE(mt7530_vlan),
.attr = mt7621_vlan,
.n_attr = ARRAY_SIZE(mt7621_vlan),
},
.get_vlan_ports = mt7530_get_vlan_ports,
.set_vlan_ports = mt7530_set_vlan_ports,

Loading…
Cancel
Save