From aa9c2149a77652e803939e1fc77dac5d35488cac Mon Sep 17 00:00:00 2001 From: Adrian Schmutzler Date: Fri, 21 Feb 2020 21:09:25 +0100 Subject: [PATCH] kirkwood: do not expose status LED to user config by default So far, the state of status LEDs is set up in 01_leds for many devices in kirkwood target. As those LEDs are also controlled by diag.sh, exposing them to the user via uci config by default seems not helpful and might even have confusing results for the user. Thus, remove the ucidef_set_led_default setup for power/status LED, but do not touch the rest where user control is actually a feature. Signed-off-by: Adrian Schmutzler --- .../kirkwood/base-files/etc/board.d/01_leds | 23 ------------------- 1 file changed, 23 deletions(-) diff --git a/target/linux/kirkwood/base-files/etc/board.d/01_leds b/target/linux/kirkwood/base-files/etc/board.d/01_leds index 504be16480..bba845eae5 100755 --- a/target/linux/kirkwood/base-files/etc/board.d/01_leds +++ b/target/linux/kirkwood/base-files/etc/board.d/01_leds @@ -10,41 +10,18 @@ board_config_update board=$(board_name) case "$board" in -"cloudengines,pogoe02") - ucidef_set_led_default "health" "health" "pogo_e02:green:health" "1" - ucidef_set_led_default "fault" "fault" "pogo_e02:orange:fault" "1" - ;; "iom,ix2-200") ucidef_set_led_timer "health" "health" "status:white:rebuild_led" "200" "800" ;; -"linksys,audi") - ucidef_set_led_default "power" "power" "audi:green:power" "1" - ;; "linksys,viper") - ucidef_set_led_default "health" "health" "viper:white:health" "1" ucidef_set_led_default "pulse" "pulse" "viper:white:pulse" "1" ;; -"raidsonic,ib-nas62x0") - ucidef_set_led_default "health" "health" "ib62x0:green:os" "1" - ucidef_set_led_default "fault" "fault" "ib62x0:red:os" "1" - ;; -"seagate,dockstar") - ucidef_set_led_default "health" "health" "status:green:health" "1" - ucidef_set_led_default "fault" "fault" "status:orange:fault" "1" - ;; -"seagate,goflexhome"|\ -"seagate,goflexnet") - ucidef_set_led_default "health" "health" "status:green:health" "1" - ucidef_set_led_default "fault" "fault" "status:orange:fault" "0" - ;; "zyxel,nsa310b") - ucidef_set_led_default "health" "health" "nsa310:green:sys" "1" ucidef_set_led_usbhost "usb" "USB" "nsa310:green:usb" ucidef_set_led_ataport "hdd" "HDD" "nsa310:green:hdd" "1" ucidef_set_led_ataport "esata" "eSata" "nsa310:green:esata" "2" ;; "zyxel,nsa325") - ucidef_set_led_default "health" "health" "nsa325:green:sys" "1" ucidef_set_led_usbhost "usb" "USB" "nsa325:green:usb" ucidef_set_led_ataport "hdd1" "HDD1" "nsa325:green:hdd1" "1" ucidef_set_led_ataport "hdd2" "HDD2" "nsa325:green:hdd2" "2"